104 research outputs found

    Electric Conductivity Study of Porous Polyvinyl Alcohol/Graphene/Clay Aerogels: Effect of Compression

    Get PDF
    In this work, poly(vinyl alcohol) (PVOH)/graphene (GN) oxide/clay aerogels were prepared using montmorillonite (MMT) and kaolinite (KLT) as fillers. This work paves the way for the development of aerogels filled with MMT or KLT with high conductivity. The mechanical properties of the polymer/clay aerogels are enhanced by incorporating GN into these systems. These composite materials have an enhanced thermal stability, and the combination of PVOH and GN leads to interconnected channels which favored the conductivity when a clay (MMT or KLT) is added to the mixed PVOH/GN matrix. However, after compressing the samples, the conductivities drastically decreased. These results show that the design of solid MMT/GN and KLT/GN composites as aerogels allows maximizing the space utilization of the electrode volume to achieve unhindered ion transport, which seems contrary to the general design principle of electrode materials where a suitable porous structure is desired, such as in our uncompressed samples. These findings also demonstrate the potential of these materials in electrodes, sensors, batteries, pressure-sensing applications, and supercapacitors.Financial support for this research from Ministerio de Economía y Competitividad (project AGL2015-63855-C2-2-R) (MINECO/FEDER) is gratefully acknowledged.The authors acknowledge the Servei Central d’Instrumentació Científica (SCIC-UJI) and Servei Central de Suport a la Investigació Experimental (SCSIE-UV) from Universitat Jaume I and Universitat de València, respectively, for the use of instruments and staff assistance. Authors would like to acknowledge José Ortega and Raquel Oliver for experimental support

    Café Chiapas

    Get PDF
    Dentro de los motivos que nos han impulsado a profundizar en el presente proyecto de inversión, fue la idea de explotación de un sector comercial y de consumo a la alza en España y Europa como lo es el café. Es sabido, que el español promedio es un consumidor potencial de café, sin embargo, también es un mercado muy competitivo, es por esto que nuestro equipo de trabajo se dio a la tarea de idealizar una estrategia con la finalidad de dar un plus a nuestro producto, creando una ventaja competitiva y distinguiéndonos frente a la competencia

    Influence of early neurological complications on clinical outcome following lung transplant

    Get PDF
    BACKGROUND. Neurological complications after lung transplantation are common. The full spectrum of neurological complications and their impact on clinical outcomes has not been extensively studied. METHODS. We investigated the neurological incidence of complications, categorized according to whether they affected the central, peripheral or autonomic nervous systems, in a series of 109 patients undergoing lung transplantation at our center between January 1 2013 and December 31 2014. RESULTS. Fifty-one patients (46.8%) presented at least one neurological complication. Critical illness polyneuropathy-myopathy (31 cases) and phrenic nerve injury (26 cases) were the two most prevalent complications. These two neuromuscular complications lengthened hospital stays by a median period of 35.5 and 32.5 days respectively. However, neurological complications did not affect patients' survival. CONCLUSIONS. The real incidence of neurological complications among lung transplant recipients is probably underestimated. They usually appear in the first two months after surgery. Despite not affecting mortality, they do affect the mean length of hospital stay, and especially the time spent in the Intensive Care Unit. We found no risk factor for neurological complications except for long operating times, ischemic time and need for transfusion. It is necessary to develop programs for the prevention and early recognition of these complications, and the prevention of their precipitant and risk factors

    Genotyping squamous cell lung carcinoma in Colombia (Geno1.1-CLICaP)

    Get PDF
    Background: Lung cancer is a public health problem, and squamous cell carcinoma (SCC) is the second most prevalent subtype of this neoplasm. Compared to other subtypes, including adenocarcinoma, SCC is less well understood in terms of molecular pathogenesis, limiting therapeutic options among targeted agents approved for other disease subgroups. In this study, we sought to characterize the SCC genomic profile using a validated Next Generation Sequencing (NGS) platform. Methods: The comprehensive NGS assay (TruSight Tumor 170) was used in order to target the full coding regions of 170 cancer-related genes on SCC samples. PD-L1 expression in tumor cells (TCs) was assessed using clone 22C3 (Dako). Clinical outcomes were correlated with molecular profile, including progression free survival (PFS), overall response rate (ORR), and overall survival (OS). Results: A total of 26 samples were included, median age was 67 years (r, 33–83) and 53.8% were men. Tobacco consumption was identified in all subjects (mean 34-year package). For first-line treatment 80.8% of patients received cisplatin or carboplatin plus gemcitabine. In terms of molecular profile, we identified a high prevalence of inactivating mutations in TP53 (61.5%), PIK3CA (34.6%), MLL2 (34.6%), KEAP1 (38.4%), and NOTCH1 (26.9%). PD-L1 expression ranged from negative, 1, 2–49, and ≥50% in 23.1, 38.5, 26.9, and 11.5%, respectively. Interestingly, the genetic alterations did not have an effect in PFS, OS or ORR in this study. However, PDL1 expression was higher among those who had mutations in TP53 (p = 0.037) and greater expression of PDL1 was related to PIK3CA alterations (p = 0.05). Conclusions: The genomic profile of SCC encompasses important genes including TP53, PIK3CA and KEAP1. TP53 mutations could be associated with PDL1 expression, generating hypothesis regarding specific treatment options

    Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

    Full text link
    The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO

    Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

    Full text link
    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.Comment: Replaced with published version. Added journal reference and DOI. Supplemental material in the ancillary file

    Level of discomfort in critically ill paediatric patients and its correlation with sociodemographic and clinical variables, analgosedation and withdrawal syndrome. COSAIP multicentre study (Phase 2)

    Full text link
    Introduction: There are clinical and sociodemographic factors that have an impact on the comfort of the critically ill paediatric patient. The main aim of this study was to determine the level of discomfort of paediatric patients admitted to different national hospitals, and to analyse its correlation with sociodemographic and clinical variables, analgosedation, and withdrawal syndrome. Methods: An observational, analytical, cross-sectional, and multicentre study was conducted in five Spanish hospitals. The level of analgosedation was assessed once per shift over a 24 h period, using a BIS sensor, and pain with scales adapted to paediatric age population. The intensity of withdrawal syndrome was determined using the Withdrawal Assessment Tool (WAT-1) scale once per shift for 3 days. Discomfort level was simultaneous assessed using COMFORT Behaviour Scale-Spanish version (CBS-S). Results: A total of 261 critically ill paediatric patients with median age of 1.61 years (IQR = 0.35-6.55) were included. An overall discomfort score of 10.79 ± 3.7 was observed during morning compared to 10.31 ± 3.3 observed during the night. When comparing analgosedation and non-analgosedation groups, statistically differences were found in both shifts (χ2: 45.48; P =.001). At the same time, an association was observed (P <.001) between low discomfort scores and development of withdrawal syndrome development assessed with WAT-1. Conclusions: As there is a percentage of the studied population with discomfort, specific protocols need to be developed, guided by valuated and clinically tested tools, like the COMFORT Behaviour Scale-Spanish version.Introducción: Existen factores clínicos o sociodemográficos que pueden tener un impacto en el confort del paciente crítico pediátrico. El objetivo principal fue determinar el grado de disconfort de los pacientes pediátricos ingresados en las UCIP de diversos hospitales nacionales y analizar su relación con variables ocio demográficas y clínicas, sedoanalgesia y síndrome de abstinencia. Métodos: Estudio observacional, analítico, transversal y multicéntrico en 5 hospitalesespañoles. Se valoró el grado de analgosedación mediante el sensor BIS y las escalas de dolora daptadas a la edad pediátrica, una vez por turno durante 24 h. El grado de abstinencia se determinó con la escala Withdrawal Assessment Tool (WAT-1), una vez por turno durante 3 días consecutivos. Además, se valoró simultáneamente el grado de disconfort mediante la COMFORTBehavior Scale-versión española (CBS-ES).Resultados: Se incluyeron un total de 261 pacientes críticos pediátricos con una mediana de edad de 1,61 años (RIQ = 0,35-6,55). Se objetivaron puntuaciones globales de disconfort de10,79 ± 3,7 en el turno de mañana versus 10,31 ± 3,3 en el de noche. Se observó asociación estadística al comparar al grupo de pacientes analgosedados con el grupo de no analgosedadosen ambos turnos ( 2: 45,48; p = 0,001). A la vez, también se observó una relación estadística-mente significativa (p < 0,001) entre puntuaciones bajas de disconfort y menor desarrollo desíndrome de abstinencia

    Influence of early neurological complications on clinical outcome following lung transplant

    Get PDF
    Sistema Nerviós Autònom; Risc de malalties cardiovasculars; Procediments mèdics quirúrgics i invasiusSistema nervioso autónomo; Riesgo de enfermedad cardiovascular; Procedimientos médicos quirúrgicos e invasivosAutonomic Nervous System; Cardiovascular disease risk; Surgical and invasive medical proceduresBackground Neurological complications after lung transplantation are common. The full spectrum of neurological complications and their impact on clinical outcomes has not been extensively studied. Methods We investigated the neurological incidence of complications, categorized according to whether they affected the central, peripheral or autonomic nervous systems, in a series of 109 patients undergoing lung transplantation at our center between January 1 2013 and December 31 2014. Results Fifty-one patients (46.8%) presented at least one neurological complication. Critical illness polyneuropathy-myopathy (31 cases) and phrenic nerve injury (26 cases) were the two most prevalent complications. These two neuromuscular complications lengthened hospital stays by a median period of 35.5 and 32.5 days respectively. However, neurological complications did not affect patients’ survival. Conclusions The real incidence of neurological complications among lung transplant recipients is probably underestimated. They usually appear in the first two months after surgery. Despite not affecting mortality, they do affect the mean length of hospital stay, and especially the time spent in the Intensive Care Unit. We found no risk factor for neurological complications except for long operating times, ischemic time and need for transfusion. It is necessary to develop programs for the prevention and early recognition of these complications, and the prevention of their precipitant and risk factors.JG is the recipient of a grant from the Spanish Fondo de Investigaciones Sanitarias (FIS PI13-01272-FEDER)
    corecore